Place of Origin: | Shanghai China |
Brand Name: | Shenjiang |
Certification: | ASME, SGS |
Model Number: | SJ-01 |
Minimum Order Quantity: | 1 set |
---|---|
Price: | Negotiation |
Packaging Details: | plywood packing for each tank |
Delivery Time: | 15 days after received deposit |
Payment Terms: | D/A, D/P, L/C, T/T, Western Union, MoneyGram |
Supply Ability: | 2000 sets one month |
Material: | Carbon Steel Q345R | Capacity: | 2000 Liter |
---|---|---|---|
Pressure: | 10 Bar | Design Temperature: | 100 Degree |
Orientation: | Vertical | Color: | Customization |
Package: | Export Standard Packaging | ||
High Light: | air compressor holding tank,air compressor storage tank |
Vertical Type Nitrogen Air Compressor receiver tank 2m3 10 Bar Pressure Carbon Steel Air Tank
1. The Function and Precautions of air compressor receiver tank :
Air compressor receiver tank, also known as compressed air tank, is a special used to store compressed air pressure vessel, the role is used for gas buffer, to avoid frequent loading and unloading air compressor and remove most of the liquid Water, mainly with air compressor, frozen dryer, filter and other equipment supporting the use of industrial production of the power source - compressed air station.
First, the use of Air Compressor Receiver Tank. Air compressor tank in the field use mainly in the following effects: buffer, cooling, water and energy storage. If the customer's request for oil content is relatively high, it is recommended to use two after the filter (precision filter + activated carbon filter); some special industries (such as food, medicine, electronics, etc.), and even need to configure the adsorption dryer And absolute filter. (General configuration in the production site) after the disposal of the proposed configuration equipment: compressor, front gas tank, front filter, cold dry machine, rear filter, rear gas tank.
Second, the work range of air compressor Receiver tank. If the air compressor gas comes out into the tank, through the gas tank, filter, dryer. As the air compressor shrink air under the action of the gas tank, the air through the gas tank when the high-speed air flow to the gas tank wall to the confluence of the gas tank is a rapid drop in temperature, is a lot of water vapor Liquefaction, thus removing a lot of water and oil, thereby reducing the load of a large number of dryers (here we can do an experiment: in the tank when there is compressed air, the following blown valve hit full, so that gas from Drain valve outflow, not long, there will be two possible: sewage valve is cold, and can see the ice discharge, the tank because the ice block will also show the remaining 3-4 kg pressure row does not come out. In this case, the amount of cooling in the tank can be seen.) When the compressed air passes through the gas tank, because the tank can store the necessary amount of air, and the output pressure is relatively stable, the smooth air flow through the filter and filter the filter The performance is also greatly improved, so that the filter life has also been extended in the precision filter after the main tank to play a buffer and energy storage role, so that the air into the workshop stable and stable input! So the exact piping configuration should be: air compressor - gas tank - primary filter - cold and dry machine - precision filter - gas tank - user workshop.
Third, the role of air compressor receiver tank
An air receiver tank is an integral and important part of any compressed air system. Typically a receiver tank is sized at 6-10 times the flow rate of the system. So, if a compressor has a rating of 25 cfm at 100 psi, the receiver tank should be 150 cubic feet, minimum. In a compressed air system, a receiver tank provides the following benefits:
Much like a water reservoir provides water during times of drought and stores water during the wet times, an air receiver tank compensates for peak demand and helps balance the supply of the compressor with the demand of the system.
Receiver tanks are required by law to have a pressure relief valve and a pressure gauge. The relief valve should be set to 10% higher than the working pressure of the system.
2. Company Advantages
1. 30 years manufacturing experience for high quality.
2. A strong R & D team, 70 senior engineers can quickly offer drawing according to your requirements.
3.18 years famous brand, the world famous enterprises are looking for our air storage tank
4. AMSE, CE certificate has been adopted
5. 100 % quality inspection before shipping .more than 40 inspectors
6. Cooperated with high quality carbon steel manufacturer.
3. Product specifications:
Model NO. | 2.0/1.0 |
Working pressure | 1.0 Mpa |
Operating temperature | 100 °C |
Vessel diameter | 1000Di |
Total height of the container | 2846mm |
Inlet diameter | 80mm |
Outlet diameter | 80mm |
Safety valve connection | R1" |
4. Our production process
1. Lofting, marking-off & cutting.
2. Manufacturing & welding
a. Make holes
b. Crimping plate
c. Spheronization
d. Welding
e. Install
f. Circumferential welding
3. Surface treatment
a. For Carbon Steel (1)Sand blasting (2)Primer (for 2 times) (3)Finishing coat
b. For Stainless steel (1)Sand blasting OR (2) Polishing
Contact Person: Lisa Lee
Stable Pressure Air Compressor Receiver Tank , Air Compressor Vertical Storage Tank
Vertical Industrial Compressed Air Receiver Tank 10 Bar Pressure 0.6m3 Liter
Screw Type Air Compressor Receiver Tank , Air Compressor Expansion Tank
Industrial Stainless Steel Air Compressor Receiver Tanks Double Sided Welding
Food Grade Stainless Steel Compressed Air Holding Tank , Stainless Steel Storage Tanks
Horizontal Pressure Vessel Design Gas Storage Tanks , Stainless Steel Pressure Tank
Carbon Steel Diaphragm Pressure Tank Pressure Vessel For Water Booster Pump Station
Blue Diaphragm Water Well Pressure Tank , Atmospheric Pressure Storage Tank
1000 Liter Potable Water Pump Pressure Expansion Tank Replaceable Diaphragm Membrane